OPERATING INSTRUCTIONS
AGT 1060
Rev.09/2020
207
Malfunction
Cause
Solution
Differential lock.
The
differential
lock
is
engaged.
Disengage the differential lock. Refer to
the chapter “Tractor console”.
Brakes.
Low brake fluid level.
Stop the tractor in safe conditions and
shut off the engine! Check the brake
fluid level and add if necessary. Refer to
the chapter “Maintenance”. If the
malfunction
persists,
consult
an
authorized service technician. (*)
Malfunction of the sensor on
the brake fluid tank.
Sensor failure or electrical system fault.
Consult an authorized service technician.
(*)
Fuel filter.
A significant quantity of water
or condensation is present in
the fuel system.
Replace the fuel filter. Refer to the
chapter “Maintenance”.
DPF filter.
The diesel particulate filter is
blocked
and
must
be
regenerated.
Perform a forced filter regeneration.
Regeneration is automatic when the
conditions are appropriate.
If this lamp and the engine lamp are
flashing, regeneration is no longer
possible!
Contact an authorized service centre
as soon as possible to avoid serious
damage to the engine of the tractor.
(*)
Air filter.
The air filter is blocked.
Clean or replace the air filter. Refer to
the chapter “Maintenance”.
(*) - These operations should only be performed by an authorized service technician!
Summary of Contents for AGT 106
Page 202: ...OPERATING INSTRUCTIONS AGT 1060 Rev 09 2020 201 Rear left side view of the tractor Fig 237...
Page 240: ...OPERATING INSTRUCTIONS AGT 1060 Rev 09 2020 239 Fig 252 9 11 2 WIRING DIAGRAM OF THE ENGINE...
Page 241: ...OPERATING INSTRUCTIONS AGT 1060 Rev 09 2020 240 Fig 253 9 11 3 WIRING DIAGRAM OF THE DASHBOARD...
Page 242: ...OPERATING INSTRUCTIONS AGT 1060 Rev 09 2020 241 Fig 254 9 11 4 WIRING DIAGRAM OF THE CAB...
Page 244: ...OPERATING INSTRUCTIONS AGT 1060 Rev 09 2020 243 NOTES...