10-2
Section
Memory Operation
201
Operation Example
In the following example, a forced interrupt is used during positioning to execute
a sequence for returning to the origin.
Operation
starts
Operation
starts
Speed (pps)
X axis
FORCED INTERRUPT
Positioning from here
on is cancelled.
Operation
starts
1, 2, 3...
1. When the operation start switch is turned ON at the origin, the program out-
puts 1,000 pulses CW on the X axis and stops. (Independent)
(First, set the origin to “0” either by performing an origin search operation or
by executing PRESENT POSITION CHANGE.)
2. When the operation start switch turns ON, positioning is executed using the
continuous completion code. The program outputs 3,500 pulses CW on the
X axis and stops.
3. When the operation start switch is turned ON, the procedure in 2 above is
repeated.
4. When the FORCED INTERRUPT switch is turned ON during the above
positioning operation, that operation is immediately canceled and position-
ing is executed to the absolute-coordinates origin.
Setting the Unit
Unit Number: Unit #0
Unit Used:
NC113
Содержание C200HW
Страница 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Страница 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 233: ...10 7 Section Transferring and Saving Data 224 Setting of operating data area for reading data READ DATA ...
Страница 284: ...Cat No W334 E1 04 Note Specifications subject to change without notice Printed in Japan Authorized Distributor ...
Страница 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...