1-3
Section
Basic Operations
9
When the override is enabled during positioning, the target speed is changed to
the override speed.
Speed
A x 1.5
A
Override setting: 150%
Time
Override enable
0
1
The PRESENT POSITION CHANGE command changes the present position to
a specified position.
This operation compensates for the amount of mechanical play, or “looseness,”
present in gears.
A zone is a range of positions which can be defined so that flags are turned ON
whenever the present position is within the range.
Zone setting
Zone Flag
CCW
CW
ON
OFF
The STOP command decelerates positioning to a stop.
STOP
Speed
Time
1
0
Override
Changing the Present
Position
Backlash Compensation
Zones
Deceleration Stop