![Omron C200HW Скачать руководство пользователя страница 160](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329160.webp)
8-1
Section
Outline
150
8-1
Outline
During memory operation, positioning sequence data such as positions and
speeds are transferred to the internal memory of the Position Control Unit in
advance, and positioning is carried out by following the positioning sequences
according to instructions from the Programmable Controller.
Position Control Unit
Operating memory area
(2) Sequence
enabled, start
or indepen-
dent start
switched
from OFF to
ON
Start sequence No.
(1) Set by MOV instruction, etc.
Automatically output
by I/O refresh
Sequence No. setting
Transferred in advance
Sequence #0
Sequence #1
Sequence #99
Position #0
Position #1
Position #99
Speed #0
Speed #1
Speed #99
Acceleration time #1
Acceleration time #2
Acceleration time #9
Deceleration time #1
Deceleration time #2
Deceleration time #9
(1)
(2)
The positioning sequences are sent in advance by data transfer to the Position
Control Unit. After the sequence numbers to be used have been set in the oper-
ating memory area, the Sequence Number Enable is switched ON.
Start is executed when the start or independent start allocated to the operating
memory area (IR area) is turned ON.
Содержание C200HW
Страница 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Страница 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 233: ...10 7 Section Transferring and Saving Data 224 Setting of operating data area for reading data READ DATA ...
Страница 284: ...Cat No W334 E1 04 Note Specifications subject to change without notice Printed in Japan Authorized Distributor ...
Страница 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...