2-4
Section
Connecting External I/O
33
There is approximately 20 ms of output when origin search is completed in
modes 1 or 2.
Position Control Unit
24-VDC
power
supply for
output
5-VDC
power
supply
24-VDC
power
supply
+
–
OMRON R88D-UP
Servomotor Driver
24-VDC
power
supply
1.6 k
Ω
OMRON R88D-UP
Servomotor Driver
–ECRST
5
6
5
6
+
–
+
–
A1/B1
A10/B10
A2/B2
A1/B1
A10/B10
A2/B2
Position Control Unit
24-VDC
power
supply for
output
+ECRST
–ECRST
+ECRST
2-4-2 Input Connection Examples
Caution
If the switching capacity is too low it may cause damage to the switch. Connect a
switch with a switching capacity of at least 5 mA for each input.
With N.C. inputs, be sure to connect a power supply for unused terminals and
turn them on.
This section shows examples of connecting interrupt, emergency stop, and CW/
CCW limit input signals.
Error Counter Reset
Output