![Omron C200HW Скачать руководство пользователя страница 140](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329140.webp)
6-2
Section
Executing Origin Search
128
If there is a Z-phase signal during deceleration, the stop position will vary
according to the deceleration time.
Pulse output
Time
Time
Pulse output
Origin adjustment
command output
Z-phase signal
Origin proximity
input signal
Origin adjustment
command output
Start
Stop
Stop
Start
When
deceleration
time is long
When
deceleration
time is short
Origin Detection Method: 3
Deceleration starts on the rising edge of the limit input signal. After the signal
turns OFF, an origin adjustment command output turns ON. If the deceleration is
insufficient while the limit input signal is ON, there will be an error.
Pulse
output
Time
Origin
adjustment
command
output
Start
Limit input
signal
Positioning
completed
input signal
Busy Flag
Stop