![Omron C200HW Скачать руководство пользователя страница 128](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329128.webp)
5-7
Section
Saving Data
115
5-7-3 Timing Chart for Saving Data
Data cannot be saved and transferred at the same time. Attempting to do so will
result in a multiple start error (error code 8000). It is also not possible to save
data while pulses are being output. The following diagram is a timing chart for
saving data.
SAVE DATA
(n+1 , bit14)
Transferring data
(n+8, bit 14)
When the data saving operation has been completed, the Transferring Data Bit
(word n+8, bit14) is turned from ON to OFF.