![Omron C200HW Скачать руководство пользователя страница 134](http://html1.mh-extra.com/html/omron/c200hw/c200hw_operation-manual_742329134.webp)
6-2
Section
Executing Origin Search
122
Origin detection method
Origin search operation
1: Reversal mode 2
1: Takes origin signal after origin
proximity signal turns ON (
↑
).
Note
A limit signal is input and operation is stopped without deceleration.
Origin proximity input
signal
Origin input signal
Pulse output
Start
Stop
Stop
Start
CW limit (See note.)
Start Limit Stop
(Error Code: 6200)
2: Origin proximity input signal not
used
Note
A limit signal is input and a stop without deceleration will occur as a result.
Origin input
signal
Pulse output
Start
Stop
Stop Start
CW limit (See note.)
Start Limit Stop
(Error Code: 6201)
Origin search proximity speed
3: Limit input signal used instead of
origin proximity input signal
An origin detection method error (error code 1607) is generated and settings are
not possible.
Origin detection method
Origin search operation
2: Single direction mode
0: Takes origin signal after origin
proximity signal turns ON (
↑
) and
OFF (
↓
).
Note
A limit signal is input and operation is stopped without deceleration.
Origin proximity input
signal
Origin input signal
Pulse output
Start
Stop
CW limit (See note.)
Limit Stop (Error Code: 6200)
Start
CW limit (See note.)
Limit Stop
(Error Code: 6200)
Start
Содержание C200HW
Страница 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Страница 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 233: ...10 7 Section Transferring and Saving Data 224 Setting of operating data area for reading data READ DATA ...
Страница 284: ...Cat No W334 E1 04 Note Specifications subject to change without notice Printed in Japan Authorized Distributor ...
Страница 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...