10-4
Section
Linear Interpolation
213
Data Settings
The values for DM 1004 onwards are transferred when the power is turned on (or
at restart).
Address
Setting
Contents of setting
1000
3001
Sequence #0 X, Y axis designation
Completion code: automatic
1001
0000
Completion code: automatic
Dwell time #0/Acceleration time #0/
deceleration time #0
1002
0100
deceleration time #0
Initial speed #1/Target speed #0
1003
3001
Sequence #1 X, Y axis designation
Completion code: automatic
Dwell time #0
1004
0000
Dwell time #0
Acceleration time #0
Deceleration time #0
1005
0100
Deceleration time #0
Initial speed #1
Target speed #0
1006
3001
Sequence #2 X, Y axis designation
Completion code: automatic
Dwell time #0
1007
0000
Dwell time #0
Acceleration time #0
Deceleration time #0
1008
0100
Deceleration time #0
Initial speed #1
Target speed #0
1009
3001
Sequence #3 X, Y axis designation
Completion code: automatic
Dwell time #0
1010
0000
Dwell time #0
Acceleration time #0
Deceleration time #0
1011
0100
Deceleration time #0
Initial speed #1
Target speed #0
1012
3001
Sequence #4 X, Y axis designation
Completion code: automatic
Dwell time #0
1013
0000
Dwell time #0
Acceleration time #0
Deceleration time #0
1014
0100
Deceleration time #0
Initial speed #1
Target speed #0
1015
3001
Sequence #5 X, Y axis designation
Completion code: automatic
Dwell time #0
1016
0000
Dwell time #0
Acceleration time #0
Deceleration time #0
1017
0100
Deceleration time #0
Initial speed #1
Target speed #0
1018
3003
Sequence #6 X, Y axis designation
Completion code: bank end
Dwell time #0
1019
0000
Dwell time #0
Acceleration time #0
Deceleration time #0
1020
0100
Deceleration time #0
Initial speed #1
Target speed #0
Note
Addresses other than the above should be set to their factory values.
Address
Setting
Contents of setting
1300
0500
Speed #0
500 pps
1301
0000
Speed #1
0 pps
Note
Addresses other than the above should be set to their factory values.
Axis Parameters
Positioning Sequences
Speeds
Содержание C200HW
Страница 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Страница 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 233: ...10 7 Section Transferring and Saving Data 224 Setting of operating data area for reading data READ DATA ...
Страница 284: ...Cat No W334 E1 04 Note Specifications subject to change without notice Printed in Japan Authorized Distributor ...
Страница 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...