8-5
Section
Timing Chart for Memory Operation
163
Turns ON while axes are outputting pulses. Turns OFF when execution is com-
pleted. No new start can be executed while the Busy Flag is ON.
The Sequence Number Enable Bit is used when designating the sequence num-
ber for starting operation. Execution begins from the specified sequence num-
ber when START or INDEPENDENT START is turned ON after a sequence
number has been designated and the Sequence Number Enable Bit turned ON.
In the following timing chart the completion codes for the positioning sequences
are as follows, using the X axis as an example:
Sequence #10, Sequence #20: Continuous
Sequence #11, Sequence #21: Bank end
Sequence number
(word n+1, bit 00 to 07)
Sequence number
enable
(word n, bit 00)
START
(word n, bit 01)
Output pulses
Speed
Sequence number
(word I+26, bit 00 to 07)
Time
Sequence
#10
Sequence
#11
Sequence
#20
Sequence
#21
INDEPENDENT START is used for stopping at each positioning sequence. An
INDEPENDENT START operation is treated as a “terminating” positioning
sequence, stopping after a single start regardless of the completion code. A
bank end operation completion code, however, will still generate a bank end
operation.
In the following timing chart the completion codes for the positioning sequences
are as follows, using the X axis as an example:
Sequence #0, Sequence #10: Continuous
Sequence #1: Automatic
Sequence #11: Bank end
Sequence number
(word n+1, bit 00 to 07)
Sequence number
enable
(word n, bit 00)
Speed
Sequence number
(word I+26, bit 00 to 07)
Sequence
#0
INDEPENDENT
START
(word n, bit 02)
Output pulses
Positioning completed
(word n+8, bit 05)
Busy Flag
(word n+8, bit 13)
Waiting for memory
operation
(word n+8, bit 04)
Sequence
#1
Sequence
#10
Sequence
#11
Time
Note
If the INDEPENDENT START Bit is turned from OFF to ON while the Sequence
Number Enable Bit is OFF following a powerup or a restart, the sequence num-
ber error (error code 8101) will be generated.
Busy Flag
Sequence Number
Enable Bit
Timing Chart for
INDEPENDENT START
Содержание C200HW
Страница 1: ...Cat No W334 E1 04 Position Control Units SYSMAC C200HW NC113 NC213 NC413 ...
Страница 2: ...C200HW NC113 NC213 NC413 Position Control Units Operation Manual Revised July 2003 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 233: ...10 7 Section Transferring and Saving Data 224 Setting of operating data area for reading data READ DATA ...
Страница 284: ...Cat No W334 E1 04 Note Specifications subject to change without notice Printed in Japan Authorized Distributor ...
Страница 285: ...Cat No W334 E1 04 C200HW NC113 NC213 NC413 Position Control Units OPERATION MANUAL ...