manualshive.com logo in svg
background image

 

J1000 CHEAT SHEET 

OVERVIEW

The following 
procedure is a 
supplement to other 
documentation 
supplied with this 
equipment and will 
guide the user in 
properly wiring the 
J1000 and motor. It 
will also allow the 
installer to check 
motor direction and 
correct if necessary.
      

Danger: 

Improper 

wiring can and will 
cause 

 

bodily harm 

as well as damage 
to the equipment

When installing the 
system be sure to 
follow good wiring 
practices and all 
applicable codes. 
Ensure that the 
mounting of the 
various components 
are secure and that 
the environment, 
such as extreme 
dampness, poor 
ventilation etc. will 
not  cause system 
degradation. 

Please read this 
sheet and the 
Quick Start Guide 
(TOEPC71060626) 
provided with the 
J1000 thoroughly 
before attempting 
any installation. 

CHEAT SHEET

To make sure you received the correct model it is essential 
to verify the J1000 nameplate with your order; and make 
sure that the drive has the correct rating so it can be used 
with your motor. Please check the nameplate information 
as shown in the example below. 

· 

Check that the available power meets the 

input power 

requirements. 

 

· 

Ensure that the 

output power

 from the VFD is 

compatible with the motor requirements.

Mounting the J1000

The mounting of the J1000 is extremely important regarding 
environment and accessibility. Depending on your system, 
there are various models available and therefore the 
mounting dimensions (footprint) may be different. Because 
the mounting procedure is fairly extensive, it is beyond the 
scope of this document, the user is referred to the J1000 
Quick Start Guide (Manual No. TOEPC71060626) received 
with the J1000, 

Section 2 Mechanical Installation

. Match 

up the model that you received and follow the procedure 
described in the manual to ensure a safe and functional 
installation. In the case where the system has more than one 
J1000 refer to the proper clearances required for adequate 
ventilation.  

Please pay particular attention to: 

  

· 

The clearances to be maintained around the enclosure 
for adequate ventilation.

 

· 

The environmental specifications such as avoiding 
excessive dampness, extreme temperatures, chemical 
exposure, corrosive areas etc. to avoid damage to the 
equipment and to maintain safety. 

 

Removing Protective Covers

Improper removal of the J1000 front cover and terminal 
cover can cause extensive damage to the J1000. To avoid 
damage to these items, please pay particular attention to the 
J1000 Quick Start Guide, Section 3.5, 

Protective Covers.   

· 

In the case of systems with multiple VFDs follow this 
procedure for each VFD and motor connected. 

IP20 / Open Chassis

Remove the Front Cover

Remove the Terminal Cover

U/T1 V/T2 W/T3

3Ø Induction 

motor

1Ø Input 

Power

Connect 
frame to 

ground

Input

Protection

(Fuse or C.B.)

To change direction of 

motor rotation swap any 

two 

of the

 three 

motor 

leads (See Step 2)

L1 L2

Fig. 1:

 Input Power and Output Motor Electrical

                Connections for Single Phase Input J1000 

WARNING DO NOT CONNECT ANY OF THE 

FOLLOWING TERMINALS TO EARTH GROUND

SINGLE PHASE 

INPUT J1000

(R/L1)

(S/L2)

(U/T1)

(V/T2)

Connect to 

chassis 

ground

Fig.1 & 2 

below show the electrical connections for the 

input power and motor terminals for various J1000 Drive 
Models.

 

Select the proper diagram for the single or three 

phase model you are installing 

(see Step 1)

 and 

WITH 

POWER OFF 

make the appropriate connections.

Make sure to follow good wiring practices and all 
applicable codes. Ensure that the equipment is 
grounded properly as shown.

DANGER, 

LETHAL VOLTAGES ARE PRESENT- Before 

applying power to the J1000, ensure that all protected 
covers are fastened and all wiring connections are 
secure. After the power has been turned OFF, wait at 
least five minutes until the charge indicator 
extinguishes completely before touching any wiring, 
circuit boards or components. 

!

R/L1 S/L2

U/T1 V/T2 W/T3

3Ø Induction 

motor

3Ø Input 

Power

Connect 
frame to 

ground

Input

Protection

(Fuse or C.B.)

To change direction of 

motor rotation swap any 

two 

of the

 three 

motor 

leads (See Step 2)

L1 L2 L3

Fig. 2: 

Input Power and Output Motor Electrical

               Connections for Three Phase Input J1000 

(R/L1)

(S/L2)

(T/L3)

(U/T1)

(V/T2)

(W/T3)

Connect to 

chassis 

ground

R/L1 S/L2 T/L3

B1

B2

-

+1

+2

(W/T3)

THREE PHASE 

INPUT J1000

Step

2

Step

1

J1000 Model Identification and 

Mounting 

Connect Motor and  

Line Power 

Step

3

Step

4

Check Motor Direction 

How to Change Parameters 

Fig. 3  Digital Operator

Next, press the

Using Safety precaution, and referring to

 Fig.1 or 2,

 swap any 

two

 

of the 

three

 output leads to the motor (U/T1, V/T2 and W/T3). After 

the wiring change, repeat 

Step 3 

and recheck motor direction.  

 

 After the power has been turned OFF, wait at least five 
minutes until the charge indicator extinguishes completely 
before touching any wiring, circuit boards or components.

DANGER 

If motor rotation is not correct, then power down the J1000 Drive.

should turn on. 

Key on the Digital Operator; the green LED

!

In this step the motor is checked for proper direction and 
operation. This test is to be performed solely from the 
digital operator. Apply power to the J1000 after all the 
electrical connections have been made and protective 
covers have been re-attached. At this point, 

DO NOT RUN 

THE MOTOR

, the Digital Operator should display as 

shown below in 

Fig. 3

.

Next, press the

key on the Digital Operator once, then press

button.

the

Next, press the

key on the Digital Operator. The motor

should now be operating at low speed running in the correct forward 
(clockwise) direction.

Next, press the

key on the Digital Operator.

REV LED

 

OFF

First Digit Flashing

First Digit Flashing

Digital Operator 

turned off.

Page 1 of 2 

YEA Document Number: TM.J1000.01  10/15/2008  ©2008 Yaskawa Electric America, Inc. - (800) YASKAWA (927-5292)     Fax (847) 887-7310     [email protected]    www.yaskawa.com

This step shows how to access and modify a J1000 parameter as 
well as how to monitor J1000 signals such as output frequency 
and motor current. Make sure all protective covers have been re-
attached and power is turned on.  

DO NOT RUN THE MOTOR. 

Press the

key once. 

key.

The digital operator shows the parameter

menu (PAr) then press the 

J1000 Digital Operator power-up state

Press the                 key to select the digit

you would like to change. Next use the

             and                 keys to select the 

parameter group, sub-group or number

Modify the parameter value using the 

              and                key and press 

the                    key to save the new value.
 

Access Parameter Menu and Change Parameter Value

Monitor Motor Frequency and Motor Current

Press the                 key until the 

FOUT

 

LED turns on. The display now shows 

the actual drive output frequency in Hz. 

Pressing the                 key again will 

show the motor output current. The ‘A’ 

behind the value means ‘Amps’.

Please refer to the technical manual 
on how to access other drive signals.

J1000 Digital Operator power-up state

Motor Current

Output Frequency

Change Parameter Value

Select Parameter

Select Parameter Menu

Отзывы: