Parameters
(N) Operation via communication and its settings
FR-F800
5 - 489
The signal within parentheses ( ) is the initial status. The description changes depending on the
setting of Pr. 180 to Pr. 189 (input terminal function selection) (page 5-279).
For each of the assigned signals, some signals are enabled by NET and some are disabled. (Refer
to page 5-132.)
The inverter run enable signal is in the initial status for the separated converter type.
The signal within parentheses ( ) is the initial status. The description changes depending on the
setting of Pr. 190 to Pr. 196 (output terminal function selection) (page 5-226).
No function is assigned in the initial status for the separated converter type.
Enable/disable parameter writing by Pr. 79 and Pr. 340 settings. For the details, refer to page 5-125.
Restrictions in each operation mode conform with the computer link specification.
●
Real-time monitor
Refer to page 5-193 for the register numbers and monitored items of the real time monitor.
Bit
Definition
Control input command
Inverter status
0
Stop command
1
Forward rotation command
During forward rotation
2
Reverse rotation command
During reverse rotation
3
RH (High-speed operation command)
SU (Up to frequency)
4
RM (Middle-speed operation command)
OL (Overload warning)
5
RL (Low-speed operation command)
IPF (Instantaneous power failure/undervoltage)
6
JOG (Jog operation selection)
FU (Output frequency detection)
7
RT (Second function selection)
8
AU (Terminal 4 input selection)
ABC2 (
⎯
9
CS (No function)
Safety monitor output
10
MRS (Output stop)
0
11
STP (STOP) (Start self-holding selection)
0
12
RES (Inverter reset)
0
13
0
0
14
0
0
15
0
Fault occurrence
Tab. 5-254:
Inverter status/control input command
Mode
Read value
Write value
EXT
H0000
H0010
PU
H0001
H0011
EXT
JOG
H0002
⎯
PU
JOG
H0003
⎯
NET
H0004
H0014
PU+EXT
H0005
⎯
Tab. 5-255:
Operation mode/inverter setting
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......