![Mitsubishi Electric FR-F800 Скачать руководство пользователя страница 269](http://html.mh-extra.com/html/mitsubishi-electric/fr-f800/fr-f800_instruction-manual_1811884269.webp)
Parameters
(F) Setting of acceleration/deceleration time and acceleration/deceleration pattern
FR-F800
5 - 107
Variable-torque acceleration/deceleration (Pr. 290 = "6")
This function is suitable to accelerate/decelerate a variable torque load such as a fan and blower in a
short time.
Linear acceleration/deceleration is performed in the area where the output frequency > base fre-
quency.
I002561E_B
Fig. 5-24:
Characteristic for parameter 29 = 6
NOTES
When the base frequency is out of the range 45 to 65 Hz, the linear acceleration/deceleration is
performed even if Pr. 29 = "6".
Even if Pr. 14 "Load pattern selection" = "1 (variable torque load)", variable torque acceleration/
deceleration setting is prioritized and the inverter operates as Pr. 14 = "0 (constant torque load)".
For the variable torque acceleration/deceleration time setting, set the time period to reach Pr. 3
"Base frequency". (Not the time period to reach Pr. 20 "Acceleration/deceleration reference fre-
quency".)
The variable torque acceleration/deceleration is disabled during PM motor control. (Linear accel-
eration/deceleration is performed.)
Parameters referred to
Pr. 3
Base frequency
=>
Pr. 7
Acceleration time
=>
Pr. 8
Deceleration time
=>
Pr. 20
Acceleration/deceleration reference frequency
=>
Pr. 10
DC injection brake operation frequency
=>
Pr. 178 to Pr. 182
(input terminal function selection)
=>
[Variable-torque acceleration/deceleration]
Pr. 3 "Base frequency"
Set frequency
Time
Pr. 8
Pr. 7
Acceleration time
Deceleration time
Output frequency
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......