Appendix
Parameters (functions) and instruction codes under different control methods
FR-F800
A - 15
721
Starting magnetic pole position detection pulse
width
15
95
7
x
x
x
724
Motor inertia (exponent)
18
98
7
x
x
725
Motor protection current level
19
99
7
x
x
726
Auto Baudrate/Max Master
1A
9A
7
727
Max Info Frames
1B
9B
7
728
Device instance number (Upper 3 digits)
1C
9C
7
729
Device instance number (Lower 4 digits)
1D
9D
7
738
Second motor induced voltage constant (phi f )
26
A6
7
x
x
x
739
Second motor Ld decay ratio
27
A7
7
x
x
x
740
Second motor Lq decay ratio
28
A8
7
x
x
x
741
Second starting resistance tuning compensation
29
A9
7
x
x
x
742
Second motor magnetic pole detection pulse
width
2A
AA
7
x
x
x
743
Second motor maximum frequency
2B
AB
7
x
x
744
Second motor inertia (integer)
2C
AC
7
x
x
745
Second motor inertia (exponent)
2D
AD
7
x
x
746
Second motor protection current level
2E
AE
7
x
x
753
Second PID action selection
35
B5
7
754
Second PID control automatic switchover
frequency
36
B6
7
755
Second PID action set point
37
B7
7
756
Second PID proportional band
38
B8
7
757
Second PID integral time
39
B9
7
758
Second PID differential time
3A
BA
7
759
PID unit selection
3B
BB
7
760
Pre-charge fault selection
3C
BC
7
761
Pre-charge ending level
3D
BD
7
762
Pre-charge ending time
3E
BE
7
763
Pre-charge upper detection level
3F
BF
7
764
Pre-charge time limit
40
C0
7
765
Second pre-charge fault selection
41
C1
7
766
Second pre-charge ending level
42
C2
7
767
Second pre-charge ending time
43
C3
7
768
Second pre-charge upper detection level
44
C4
7
769
Second pre-charge time limit
45
C5
7
774
Operation panel monitor selection 1
4A
CA
7
775
Operation panel monitor selection 2
4B
CB
7
776
Operation panel monitor selection 3
4C
CC
7
777
4 mA input check operation frequency
4D
CD
7
778
4 mA input check filter
4E
CE
7
779
Operation frequency during communication error
4F
CF
7
791
Acceleration time in low-speed range
5B
DB
7
x
x
792
Deceleration time in low-speed range
5C
DC
7
x
x
799
Pulse increment setting for output power
63
E3
7
Pr.
Name
Instruction code
Control method
Parameter
Read
Wr
it
e
Ext
e
n
d
e
d
Co
p
y
Clea
r
Al
l cl
ea
r
Tab. A-3:
Parameter list with instruction codes (11)
V/F
V/FV/FV/F
Magnetic fluxMagnetic fluxMagnetic flux
PMPMPM
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......