(C) Motor constant parameters
Parameters
5 - 310
5.10.3
Offline auto tuning for a PM motor (motor constants tuning)
The offline auto tuning for a PM motor enables the optimal operation of a PM motor.
What is offline auto tuning?
Under PM motor control, setting motor constants automatically (offline auto tuning) enables optimal
operation of motors even when motor constants vary or when the wiring distance is long. IPM and
SPM motors other than IPM motor MM-EFS/MM-THE4 can also be used.
For the offline auto tuning under Advanced magnetic flux vector control, refer to page 5-42.
Pr.
Name
Initial
value
Setting range
Description
684
C000
Tuning data unit switchover
0
0
Internal data converted value
1
The value is indicated with "A, Ω, mH
or mV".
1002
C150
Lq tuning target current
adjustment coefficient
9999
50 to 150%
Perform adjustment if the
overcurrent protective function is
activated during tuning.
9999
No adjustment
71
C100
Applied motor
0
0 to 6, 13 to 16, 20, 23, 24, 40,
43, 44, 50, 53, 54, 70, 73, 74,
210, 213, 214, 240, 243, 244,
8090, 8093, 8094, 9090, 9093,
9094
By selecting a motor, the thermal
characteristic and motor constant of
each motor are set.
80
C101
Motor capacity
9999
Applied motor capacity setting.
0 to 3600 kW
9999
V/F control
81
C102
Number of motor poles
9999
2, 4, 6, 8, 10, 12
Set the number of motor poles.
9999
V/F control
9
C103
Electronic thermal O/L relay
Rated
inverter
current
0 to 500 A
Set the rated motor current.
0 to 3600 A
83
C104
Rated motor voltage
200/
400 V
0 to 1000 V
Set the rated motor voltage (V).
84
C105
Rated motor frequency
9999
10 to 400 Hz
Set the rated motor frequency (Hz).
9999
The MM-EFS/MM-THE4 constant is
used when the IPM motor MM-EFS/
MM-THE4 is selected, and the
inverter internal data is used when a
PM motor other than MM-EFS/MM-
THE4 is selected. Use the correct
setting according to the motor
specification.
702
C106
Maximum motor frequency
9999
0 to 400 Hz
Set the maximum frequency of the
motor.
9999
The MM-EFS/MM-THE4motor
maximum frequency is used when
the IPM motor MM-EFS/MM-THE4 is
selected, and Pr. 84 setting is used
when a PM motor other than MM-
EFS/MM-THE4 is selected.
707
C107
Motor inertia (integer)
9999
10 to 999, 9999
Set the motor inertia.
9999: Uses MM-EFS/MM-THE4 inertia
for IPM motor MM-EFS/MM-THE4
724
C108
Motor inertia (exponent)
9999
0 to 7, 9999
96
C110
Auto tuning setting/status
0
0, 101
No offline auto tuning.
1
Performs offline auto tuning without
rotating the motor. (motor other
than IPM motor MM-EFS/MM-THE4)
11
Performs offline auto tuning without
rotating the motor (V/F control, IPM
motor MM-EFS/MM-THE4).
PM
PM
PM
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......