Mount the unit
Din-Rail mount: Mount the din-rail clip on the rear of JetCon 25301 on
the DIN rail. For information about the DIN Rail installation, please
refer to user’s manual.
Grounding JetCon 2301S
There is one grounding screw on the
bottom side of JetCon 2301S. Connect the
frame grounding of JetCon 2301S to the
grounding surface to ensure safety and
prevent noise for communication interference.
Wiring the Power Inputs
1. Insert the positive and negative wires into the V+ and V- contact on
the terminal block connector.
2. Tighten the wire-clamp screws to prevent the power wires loosened.
Note:
The recommended working voltage is DC 24V. (Input range: DC10~ 60 V)
JetCon 2301S is a single port Fast Ethernet to Fiber media converter,
supporting 4 types of forwarding modes – Store and Forward,
Modified Cut-through, Pure Converter and Converter with auto-
change modes. JetCon 2301S with IP31 grade enclosure and 1.5KV
Hi-Pot isolation protection to operate in harsh environments with
severe electromagnetic interference and -40~70
°
C.
JetCon 2301S
Quick Installation Guide v1.0
Copyright
Copyright © 2014 all rights reserved. No part of this publication may
be reproduced, adapted, stored in a retrieval system, translated into
any language, or transmitted in any form or by any means without
the written permission of the supplier.
About the Quick Installation Guide
This Quick Installation Guide is intended to guide professional
installer to install and configure the JetCon 2301S. It covers
procedures to assist you in avoiding unforeseen problems.
Installation
Introduction
2.
Connecting the Fiber Port: Connect the fiber port on your JetCon
2301S to another Fiber Ethernet device, by following the figure
below. Wrong connection or fiber cable type will cause the fiber
port not working properly.
3.
For different link distance,
the JetCon 2301S provides
JetCon 2301S-mw” for
multi-mode fiber and
“JetCon 2301S-sw” for
single-mode fiber.
4.
The table below illustrates fiber
transceiver specification.
Wiring the Relay Output
The relay output contacts are in the middle of the terminal block connector
as shown below. By inserting the wires and settings the DIP switch of the
respective alarm function to “ON”, relay output alarm will detect port or
power fault, and form a short circuit. The alarm relay output is “Normal
Open”. For more information, please refer Manual chapter for more detail.
Note:
The relay contact only support 1A current, DC 24V. It does not recommend
apply higher voltage and current that over this specification.
Connecting to Network
1.
Connecting the Ethernet Port: Connect one end of an Ethernet cable
into the UTP port of JetCon 2301S, while the other end is connected
to the attached networking device. UTP port support auto
MDI/MDIX function. The LNK / ACT LED will turn on and flash to
indicate RJ-45 port link and the packets received and transmitted
from RJ-45.
Note:
To ensure your fiber converter can transmit/receive data between the
2 nodes, the attenuation of the optical fiber cable should be smaller
than the fiber converter’s Link Budget.
Attention:
This is a Class 1 Laser/LED product. Don’t stare into the Laser/LED
Beam.
DIP Switch Setting
Note:
After adjusting the DIP-switch, please reboot the unit to activate the
new settings.
Package Check List
JetCon 2301S Industrial Media Converter
Quick Installation Guide
5 Years Warranty
Each of Korenix’s product line is designed, produced, and tested with
high industrial standard. Korenix warrants that the Product(s) shall be
free from defects in materials and workmanship for a period of five (5)
years from the date of delivery provided that the Product was properly
installed and used.
This is warranty is voided if defects, malfunctions or failures of the
warranted Product are caused by damage resulting from force measure
(such as floods, fire, etc.), other external forces such as power
disturbances, over spec power input, or incorrect cabling; or the
warranted product is misused, abused, or operated, altered and
repaired in an unauthorized or improper way.
Attention! To avoid system damage caused by sparks, please DO NOT
plug in power connector when power is on.
The product is in compliance with Directive 2002/95/EC and 2011/65/EU
of the European Parliament and of the Council of 27 January 2003 on the
restriction of the use of certain hazardous substances in electrical and
electronics equipment (RoHS Directives & RoHS 2.0)