![Mitsubishi Electric FR-F800 Скачать руководство пользователя страница 725](http://html.mh-extra.com/html/mitsubishi-electric/fr-f800/fr-f800_instruction-manual_1811884725.webp)
Protective functions
The list of fault displays
FR-F800
6 - 5
6.4
The list of fault displays
If the displayed message does not correspond to any of the following or if you have any other prob-
lem, please contact your sales representative.
Error message
A message regarding operational fault and setting fault by the operation panel and the parameter
unit is displayed. The inverter does not trip.
Warning
The inverter does not trip even when a warning is displayed. However, failure to take appropriate
measures will lead to a fault.
Operation panel indication
Name
Refer to
page
E---
Faults history
HOLD
Operation panel lock
LOCD
Password locked
to
Er1 to Er4,
Er8
Parameter write error
to
to
rE1 to rE4
rE6 to rE8
Copy operation error
Err.
Error
Tab. 6-4:
Error message
Operation panel indication
Name
Refer to
page
OL
Stall prevention (overcurrent)
oL
Stall prevention (overvoltage)
TH
Electronic thermal relay function pre-alarm
PS
PU stop
CP
Parameter copy
SA
Safety stop
to
MT1 to MT3
Maintenance signal output
UF
USB host error
EV
24 V external power supply operation
ED
Emergency drive in operation
LDF
Load fault warning
Tab. 6-5:
Warning
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......