Parameters
Parameter List
FR-F800
5 - 15
M
o
tor constan
ts
738
C230
Second motor induced voltage
constant (phi f )
0 to 5000 mV/(rad/s),
9999
0.1 mV/(rad/s)
9999
739
C231
Second motor Ld decay ratio
0 to 100%, 9999
0.1%
9999
740
C232
Second motor Lq decay ratio
0 to 100%, 9999
0.1%
9999
741
C282
Second starting resistance tuning
compensation
0 to 200%, 9999
0.1%
9999
742
C285
Second motor magnetic pole detection
pulse width
0 to 6000 μs,
10000 to 16000 μs,
9999
1 μs
9999
743
C206
Second motor maximum frequency
0 to 400 Hz, 9999
0.01 Hz
9999
744
C207
Second motor inertia (integer)
10 to 999, 9999
1
9999
745
C208
Second motor inertia (exponent)
0 to 7, 9999
1
9999
746
C233
Second motor protection current level
100 to 500%, 9999
0.1%
9999
PI
D
co
n
tr
o
l
753
A650
Second PID action selection
0, 10, 11, 20, 21, 50, 51,
60, 61, 70, 71, 80, 81, 90,
91, 100, 101, 1000, 1001,
1010, 1011, 2000, 2001,
2010, 2011
1
0
754
A652
Second PID control automatic
switchover frequency
0 to 590 Hz, 9999
0.01 Hz
9999
755
A651
Second PID action set point
0 to 100%, 9999
0.01%
9999
756
A653
Second PID proportional band
0.1 to 1000%, 9999
0.1%
100%
757
A654
Second PID integral time
0.1 to 3600 s, 9999
0.1 s
1 s
758
A655
Second PID differential time
0.01 to 10 s, 9999
0.01 s
9999
759
A600
PID unit selection
0 to 43, 9999
1
9999
PID pr
e
-c
h
ar
ge
func
ti
on
760
A616
Pre-charge fault selection
0, 1
1
0
761
A617
Pre-charge ending level
0 to 100%, 9999
0.1%
9999
762
A618
Pre-charge ending time
0 to 3600 s, 9999
0.1 s
9999
763
A619
Pre-charge upper detection level
0 to 100%, 9999
0.1%
9999
764
A620
Pre-charge time limit
0 to 3600 s, 9999
0.1 s
9999
765
A656
Second pre-charge fault selection
0, 1
1
0
766
A657
Second pre-charge ending level
0 to 100%, 9999
0.1%
9999
767
A658
Second pre-charge ending time
0 to 3600 s, 9999
0.1 s
9999
768
A659
Second pre-charge upper detection
level
0 to 100%, 9999
0.1%
9999
769
A660
Second pre-charge time limit
0 to 3600 s, 9999
0.1 s
9999
Mo
n
it
o
r
func
tion
774
M101
Operation panel monitor selection 1
1 to 3, 5 to 14, 17, 18, 20,
23 to 25, 34, 38, 40 to 45,
50 to 57, 61, 62, 64, 67 to
69, 81 to 96, 98, 100,
9999
1
9999
775
M102
Operation panel monitor selection 2
1
9999
776
M103
Operation panel monitor selection 3
1
9999
⎯
777
A681
4 mA input check operation frequency
0 to 590 Hz, 9999
0.01 Hz
9999
T053
⎯
778
A682
4 mA input check filter
0 to 10 s
0.01 s
0 s
T054
⎯
779
N014
Operation frequency during
communication error
0 to 590 Hz, 9999
0.01 Hz
9999
⎯
791
F070
Acceleration time in low-speed range
0 to 3600 s, 9999
0.1 s
9999
⎯
792
F071
Deceleration time in low-speed range
0 to 3600 s, 9999
0.1 s
9999
⎯
799
M520
Pulse increment setting for output
power
0.1, 1, 10, 100, 1000 kWh
0.1 kWh
1 kWh
⎯
800
G200
Control method selection
9, 20
1
20
Fu
n
c
ti
o
n
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value
Refer
to page
Cu
st
o
m
e
r
setting
FM
CA
Tab. 5-2:
Parameter overview (by number) (14)
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......