8.1.2 400
V
class
For footnotes
to
&
refer to page 8-3.
For footnotes
to
&
refer to page 8-3.
Model FR-F840-
00023
(0.75K)
00038
(1.5K)
00052
(2.2K)
00083
(3.7K)
00126
(5.5K)
00170
(7.5K)
00250
(11K)
00310
(15K)
00380
(18.5K)
00470
(22K)
00620
(30K)
00770
(37K)
00930
(45K)
01160
(55K)
01800
(75K)
02160
(90K)
02600
(110K)
Applicable motor capacity
[kW]
SLD
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75/90
110
132
LD
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
Ou
tp
ut
Rated capacity [kVA]
SLD
1.8
2.9
4
6.3
10
13
19
24
29
36
47
59
71
88
137
165
198
LD
1.6
2.7
3.7
5.8
8.8
12
18
22
27
33
43
53
65
81
110
137
165
Rated current
[A]
SLD
2.3
3.8
5.2
8.3
12.6
17
25
31
38
47
62
77
93
116
180
216
260
LD
2.1
3.5
4.8
7.6
11.5
16
23
29
35
43
57
70
85
106
144
180
216
Overload current rating
SLD
110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature of 40 °C
LD
120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C
Rated voltage
Three-phase 380 to 500 V
Po
w
er
s
up
pl
y
Rated input AC voltage/frequency
Three-phase 380 to 500 V 50 Hz/60 Hz
&
Permissible AC voltage fluctuation
323 to 550 V 50 Hz/60 Hz
Permissible frequency fluctuation
±5%
Rated input current [A]
"
SLD
3.2
5.4
7.8
10.9
16.4
22.5
31.7
40.3
48.2
58.4
76.8
97.6
115
141
180
216
260
LD
3
4.9
7.3
10.1
15.1
22.3
31
38.2
44.9
53.9
75.1
89.7
106
130
144
180
216
Power supply capacity
[kVA]
!
SLD
2.5
4.1
5.9
8.3
12
17
24
31
37
44
59
74
88
107
137
165
198
LD
2.3
3.7
5.5
7.7
12
17
24
29
34
41
57
68
81
99
110
137
165
Protective structure (IEC 60529)
Enclose type (IP20)
Open type (IP00)
Cooling system
Self-cooling
Forced air cooling
Approx. mass [kg]
2.5
2.5
2.5
3.0
3.0
6.3
6.3
8.3
8.3
15
15
23
41
41
43
52
55
Tab. 8-2:
Specifications FR-F840-00023(0.75K) to 02600(110K)
Model FR-F840-
03250
(132K)
03610
(160K)
04320
(185K)
04810
(220K)
05470
(250K)
06100
(280K)
06830
(315K)
Applicable motor capacity
[kW]
SLD
160
185
220
250
280
315
355
LD
132
160
185
220
250
280
315
Output
Rated capacity [kVA]
SLD
248
275
329
367
417
465
521
LD
198
248
275
329
367
417
465
Rated current [A]
SLD
325
361
432
481
547
610
683
LD
260
325
361
432
481
547
610
Overload current rating
SLD
110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature of 40 °C
LD
120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C
Rated voltage
Three-phase 380 to 500 V
Po
w
er
su
pp
ly
Rated input AC voltage/frequency
Three-phase 380 to 500 V 50 Hz/60 Hz
&
Permissible AC voltage fluctuation
323 to 550 V 50 Hz/60 Hz
Permissible frequency fluctuation
±5%
Rated input current
[A]
"
SLD
325
361
432
481
547
610
683
LD
260
325
361
432
481
547
610
Power supply capacity
[kVA]
!
SLD
248
275
329
367
417
465
521
LD
198
248
275
329
367
417
465
Protective structure (IEC 60529)
Open type (IP00)
Cooling system
Forced air cooling
Approx. mass [kg]
71
78
117
117
166
166
166
Tab. 8-3:
Specifications FR-F840-03250(132K) to 06830(315K)
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......