Basic operation procedure (JOG operation)
Basic operation
4 - 30
4.7 Basic
operation
procedure (JOG operation)
4.7.1
Performing JOG operation using external signals
Connection diagram
쑶
NOTES
Perform JOG operation only while the JOG signal is ON.
Use Pr. 15 "Jog frequency" and Pr. 16 "Jog acceleration/deceleration time" for the operation.
Set Pr. 79 "Operation mode selection" ="2" (External operation mode).
I002434E
Fig. 4-12:
JOG operation by external signals
Example
쑴
Operation example: Operate at 5 Hz.
Operation
Screen at power-ON
The monitor display appears.
Turning ON the JOG signal
Turn ON the JOG switch (JOG). The inverter is set ready for the JOG operation.
Start
➔
acceleration
➔
constant speed
Turn ON the start switch (STF or STR). The frequency value on the indication increases in Pr. 16 "Jog acceleration/
deceleration time", and "
" (5.00 Hz) appears. [FWD] indicator is lit during the forward rotation, and [REV]
indicator is lit during the reverse rotation.
Deceleration
➔
stop
Turn OFF the start switch (STF or STR). The frequency value on the indication decreases in Pr. 16 "Jog acceleration/
deceleration time", and the motor stops rotating with "
" (0.00 Hz) displayed. [FWD] or [REV] indicator turns
OFF. Turn OFF the JOG switch (JOG).
Tab. 4-21:
JOG operation in the external operation mode
NOTES
To change the running frequency, change Pr. 15 "Jog frequency" (initial value "5 Hz").
To change the acceleration/deceleration time, change Pr. 16 "Jog acceleration/deceleration time"
(initial value "0.5 s").
Parameters referred to
Pr. 15
Jog frequency
=>
Pr. 16
Jog acceleration/deceleration time
=>
Pr. 79
Operation mode selection
=>
STF
SD
JOG
STR
Inverter
Reverse rotation start
Switch
Forward rotation start
JOG signal
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......