(T) Multi-Function Input Terminal Parameters
Parameters
5 - 286
●
When the RT signal is ON, the following second functions are selected at the same time.
The function can be changed by switching the RT signal ON/OFF while the inverter is stopped. If
a signal is switched during operation, the operation method changes after the inverter stops,
(Pr. 450
≠
9999).
Function
First function
Parameter number
Second function
Parameter number
Refer to page
Torque boost
Pr. 0
Pr. 46
Base frequency
Pr. 3
Pr. 47
Acceleration time
Pr. 7
Pr. 44
Deceleration time
Pr. 8
Pr. 44, Pr. 45
Electronic thermal O/L relay
Pr. 9
Pr. 51
Free thermal
Pr. 600 to Pr. 604
Pr. 692 to Pr. 696
Motor permissible load level
Pr. 607
Pr. 608
Stall prevention
Pr. 22
Pr. 48, Pr. 49
Pr. 71
Pr. 450
Motor constant
Pr. 80 to Pr. 84,
Pr. 89 to Pr. 94, Pr. 298,
Pr. 702, Pr. 706, Pr. 707,
Pr. 711, Pr. 712, Pr. 717,
Pr. 721, Pr. 724, Pr. 725,
Pr. 859
Pr. 453 to Pr. 457, Pr. 560,
Pr. 569, Pr. 458 to Pr. 462,
Pr. 738 to Pr. 747, Pr. 860
Offline auto tuning
Pr. 96
Pr. 463
Online auto tuning
Pr. 95
Pr. 574
PID control
Pr. 127 to Pr. 134
Pr. 753 to Pr. 758
Pr. 760 to Pr. 764
Pr. 765 to Pr. 769
Speed control gain
Pr. 820, Pr. 821
Pr. 830, Pr. 831
Analog input filter
Pr. 822, Pr. 826
Pr. 832, Pr. 836
Torque control gain
Pr. 824, Pr. 825
Pr. 834, Pr. 835
Torque detection filter
Pr. 827
Pr. 837
Tab. 5-128:
Functions, that can be set as second functions
NOTES
RT signal is assigned to the terminal RT in the initial status. Set "3" in any of Pr. 178 to Pr. 189 (input
terminal function selection) to assign the RT signal to another terminal.
Changing the terminal assignment using Pr. 178 to Pr. 189 (input terminal function selection) may
affect the other functions. Set parameters after confirming the function of each terminal.
Parameters referred to
Pr. 178 to Pr. 189
(input terminal function selection)
=>
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......