Installation and wiring
Communication connectors and terminals
FR-F800
2 - 63
2.7.2 USB
connector
USB host communication
●
Different inverter data can be saved in a USB memory device.
The USB host communication enables the following functions.
●
When the inverter recognizes the USB memory device without any problem, "USB.–A" is briefly
displayed on the operation panel.
●
When the USB memory device is removed, "USB.–" is briefly displayed on the operation panel.
I003012E
Fig. 2-44:
USB connector
Specification
Description
Interface
Conforms to USB1.1
Transmission speed
12 Mbps
Wiring length
Maximum 5 m
Connector
USB A connector (receptacle)
Compatible USB
memory
Format
FAT32
Capacity
1 GB or more (used in the recorder mode of the trace function)
Encryption function
Not available
Tab. 2-29:
USB connector specification
Function
Description
Refer to
page
Parameter copy
Copies the parameter setting from the inverter to the USB memory device. The
maximum of 99 parameter setting files can be saved in a USB memory device.
The parameter setting data copied in the USB memory device can be copied to other
inverters. This function is useful in backing up the parameter setting or for sharing the
parameter setting among multiple inverters.
The parameter setting file can be copied onto a personal computer from the USB
memory device and edited using FR Configurator2.
Trace
The monitored data and output status of the signals can be saved in a USB memory
device.
The saved data can be imported to FR Configurator2 to diagnose the operating status of
the inverter.
PLC function
data copy
This function copies the PLC function project data to a USB memory device when the PLC
function is used.
The PLC function project data copied in the USB memory device can be copied to other
inverters.
This function is useful in backing up the parameter setting and for allowing multiple
inverters to operate by the same sequence programs.
Tab. 2-30:
Functions enabled via the USB host communication
USB host
(A connector)
Communication status
indicator (LED)
USB device
(Mini B connector)
Place a flathead
screwdriver, etc. in a slot
and push up the cover to
open.
Personal computer
(FR Configurator2)
USB
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......