Parameters
(N) Operation via communication and its settings
FR-F800
5 - 507
●
Alarm history
C40 (933)
41933
Terminal 4 gain command (torque)
Read/write
C41 (933)
42123
Terminal 4 gain (torque)
Read/write
Analog value (%) set to C41
(933)
43933
Terminal 4 gain (torque)
(terminal analog value)
Read
Analog value (%) of the current
(voltage) applied to the terminal
4
C42 (934)
41934
PID display bias coefficient
Read/write
C43 (934)
42124
PID display bias analog value
Read/write
Analog value (%) set to C43
(934).
43934
PID display bias analog value
(terminal analog value)
Read
Analog value (%) of the current
(voltage) applied to the terminal
4.
C44 (935)
41935
PID display gain coefficient
Read/write
C45 (935)
42125
PID display gain analog value
Read/write
Analog value (%) set to C45
(935).
43935
PID display gain analog value
(terminal analog value)
Read
Analog value (%) of the current
(voltage) applied to the terminal
4.
1000 to
1999
45000 to
45999
Refer to the parameter list (page 5-2)
for parameter names.
Read/write
The parameter 44000
is the register number.
Register
Definition
Read/write
Remarks
40501
Faults history 1
Read/write
Being 2 bytes in length, the data is stored as
"H00
".
Refer to the lowest 1 byte for the error code.
(Refer to page 6-5 for the error codes.)
Performing write using the register 40501
batch-clears the faults history.
Set any value as data.
40502
Faults history 2
Read
40503
Faults history 3
Read
40504
Faults history 4
Read
40505
Faults history 5
Read
40506
Faults history 6
Read
40507
Faults history 7
Read
40508
Faults history 8
Read
Tab. 5-273:
Faults history
Pr.
Register
Parameter name
Read/Write
Remarks
Tab. 5-272:
Parameter
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......