![Mitsubishi Electric FR-F800 Скачать руководство пользователя страница 769](http://html.mh-extra.com/html/mitsubishi-electric/fr-f800/fr-f800_instruction-manual_1811884769.webp)
Precautions for maintenance and inspection
Inspection item
FR-F800
7 - 9
Reinstall the fan cover.
●
Removal (FR-F840-04320(185K) or higher)
Remove the fan cover fixing screws, and remove the fan cover.
Disconnect the fan connector and remove the fan block.
Remove the fan fixing screws, and remove the fan.
I002457E, I002458E, I002459E
Fig. 7-6:
Reinstall the fan cover
I002809E
Fig. 7-7:
Removal of the fan (FR-F840-04320(185K) or higher)
FR-F820-01870(45K) or higher
FR-F840-00930(45K) to
03610(160K)
FR-F820-00340(7.5K) to 01540(37K),
FR-F840-00170(7.5K) to 00770(37K)
FR-F820-00105(2.2K) to 00250(5.5K)
FR-F840-00083(3.7K), 00126(5.5K)
Insert hooks into holes.
Insert hooks until you hear a click sound.
*
The number of cooling fans differs according to the inverter capacity.
Fan connection
connector
Fan cover
Fan *
Fan block