![Mitsubishi Electric FR-F800 Скачать руководство пользователя страница 786](http://html.mh-extra.com/html/mitsubishi-electric/fr-f800/fr-f800_instruction-manual_1811884786.webp)
Motor rating
Specifications
8 - 6
8.2.2
Premium high-efficiency IPM motor [MM-EFS (3000 r/min specification)]
●
Motor specification
The above characteristics apply when the rated AC voltage is input from the inverter. (Refer to page
8-1.) Output and rated motor speed are not guaranteed when the power supply voltage drops.
This excludes the part where the axis passes through.
For the LD rating
Motor model
200V class
MM-EFS
3
400V class
MM-EFS
34
7
15
22
37
55
75
11K
15K
Compatible
inverter
200V class
FR-F820-
00046
(0.75K)
00077
(1.5K)
00105
(2.2K)
00167
(3.7K)
00250
(5.5K)
00340
(7.5K)
00490
(11K)
00630
(15K)
400V class
FR-F840-
00023
(0.75K)
00038
(1.5K)
00052
(2.2K)
00083
(3.7K)
00126
(5.5K)
00170
(7.5K)
00250
(11K)
00310
(15K)
Continuous
characteristic
Rated output
[kW]
0.75
1.5
2.2
3.7
5.5
7.5
11
15
Rated torque
[Nm]
2.39
4.77
7.0
11.8
17.5
23.9
35.0
47.7
Rated speed (r/min)
3000
Maximum speed (r/min)
4000
Number of poles
6
Maximum torque
120% 6s
Frame No.
80M
90L
112M
132S
160M
Inertia moment J [×10
-4
kg× m
2
]
10.7
22.4
29.8
68.3
198
534
Rated current [A]
200 V class
3.2
6.1
8.4
14.3
21.4
28.7
37.6
51.4
400 V class
1.6
3.1
4.2
7.2
10.7
14.4
18.8
25.7
Structure
Totally-enclosed fan-cooled motor. With steel framed legs. (protective structure IP44
)
Insulation class
F class
Vibration class
V15
Environment
Surrounding air
temperature,
humidity
–10°C to +40°C (non-freezing)
90%RH or less (non-condensing)
Storage
temperature,
humidity
–20°C to +70°C (non-freezing)
90%RH or less (non-condensing)
Atmosphere
Indoors (not under direct sunlight), and free from corrosive gas, flammable gas, oil mist, dust and dirt.
Altitude
Maximum 1,000 m above sea level
Vibration
4.9 m/s²
Mass [kg]
8
12
14
25
41
75
Tab. 8-5:
Motor rating MM-EFS (3000 r/min specification)
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......