Parameters
(F) Setting of acceleration/deceleration time and acceleration/deceleration pattern
FR-F800
5 - 111
The multi-speed operation function is invalid when remote setting function is selected.
Even when the remotely-set frequency is cleared by turning ON the RL (clear) signal after turning
OFF (ON) both the RH and RM signals, the inverter operates at the remotely-set frequency stored
in the last operation if power is reapplied before one minute has elapsed since turning OFF (ON)
both the RH and RM signals.
When the remotely-set frequency is cleared by turning ON the RL (clear) signal after turning OFF
(ON) both the RH and RM signals, the inverter operates at the frequency in the remotely-set fre-
quency cleared state if power is reapplied before one minute has elapsed since turning OFF (ON)
both the RH and RM signals.
E
CAUTION:
When using the remote setting function, set the maximum frequency again according to the
machine.
Parameters referred to
Pr. 1
Maximum frequency
=>
Pr. 18
High speed maximum frequency
=>
Pr. 7
Acceleration time
=>
Pr. 8
Deceleration time
=>
Pr. 44
Second acceleration/deceleration time
=>
Pr. 45
Second deceleration time
=>
Pr. 28
Multi-speed input compensation selection
=>
Pr. 178 to Pr. 182
(input terminal function selection)
=>
Setting frequency is "0".
Acceleration RH
Remotely-set frequency stored last time
Output fr
equen
c
y
[H
z]
Remotely-set frequency stored last time
ON
ON
ON
ON
ON
ON
OFF
Time
< 1 minute
Deceleration RM
Clear RL
Forward rotation STF
Power supply
Acceleration RH
O
utput fr
equen
cy
[H
z]
Remotely-set frequency stored last time
Deceleration RM
Forward rotation STF
Power supply
Clear RL
Operation is performed at the
set frequency 0 Hz.
ON
ON
ON
ON
ON
ON
OFF
Time
> 1 minute
1 minute
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......