Selecting the PM motor control by performing parameter initialization on the operation panel
(
)
NOTE
The parameters required to drive an IPM motor MM-EFS or MM-THE4 are automatically changed
as a batch. (Refer to page 5-48.)
[PM] on the operation panel (FR-DU08) is on when the PM motor control is set.
Example
쑴
Operation example: Initialize the parameter settings for an IPM motor MM-EFS (1500 r/min specifi-
cation) or MM-THE4 by selecting IPM parameter initialization on the operation panel.
Operation
Screen at power-ON
The monitor display appears.
Changing the operation mode
Press
to choose the PU operation mode.
[PU] indicator is lit.
Parameter setting mode
Press
to choose the parameter setting mode.
[PRM] indicator is lit.
IPM parameter initialization
Turn
until
(IPM parameter initialization) appears.
"
Setting value display
Press
to read the present set value.
"
" (initial value) appears.
!
Changing the setting value
Turn
to change the set value to "
", then press
.
"
" and "
" flicker alternately. The setting is completed.
Tab. 5-19:
Selecting the PM motor control by performing parameter initialization
Setting
Description
0
Parameter settings for an induction motor
12
Parameter settings for an IPM motor MM-EFS (1500 r/min specification)/MM-THE4 (rotations per minute)
14
Parameter settings for an IPM motor MM-EFS (3000 r/min specification) (rotations per minute)
Tab. 5-20:
Settings for the IPM parameter initialization
NOTES
If parameters are initialized for a PM motor in the IPM initialization mode, the Pr. 998 "PM parame-
ter initialization" setting is automatically changed.
To set a speed or to display monitored items in frequency, Pr. 998. (Refer to page 5-46.)
When Pr. 998 = "112, 114", the IPM parameter initialization (
) setting is displayed as "12, 14".
PM
PM
PM
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......