Special operation
Parameter
6 - 264
6.19.3
Traverse function (Pr. 592 to Pr. 597)
Die Funktion ermöglicht den Betrieb mit einer zyklischen Änderung der Ausgangsfrequenz. Die
Funktion wird beispielsweise in der Textilindustrie bei Wickelvorgängen verwendet.
The above parameters can be set when Pr. 160 = 0.
When "1" or "2" is set in Pr. 592, turning on the traverse operation signal (X37) makes the tra-
verse function valid.
Set "37" in any of Pr. 178 to Pr. 182 and assign the X37 signal to the external terminal. When the
X37 signal is not assigned to the input terminal, the traverse function is always valid (X37-ON).
Pr. No.
Name
Initial
Value
Setting
Range
Description
Parameters referred to
Refer to
Section
592
Traverse function
selection
0
0
Traverse function invalid
1
2
7
8
29
178–182
Maximum fre-
quency
Minimum fre-
quency
Acceleration time
Deceleration time
Acceleration/decel-
eration pattern
selection
I
nput terminal
function
selection
1
Traverse function is valid only in the
External operation mode
2
Traverse function is valid
independently of operation mode
593
Maximum amplitude
amount
10%
0–25%
Amplitude amount during traverse
operation
594
Amplitude
compensation amount
during deceleration
10%
0–50%
Compensation amount at the time of
amplitude inversion (acceleration to
deceleration)
595
Amplitude
compensation amount
during acceleration
10%
0–50%
Compensation amount at the time of
amplitude inversion (deceleration to
acceleration)
596
Amplitude
acceleration time
5 s
0.1–3600s
Acceleration time during traverse
operation
597
Amplitude
deceleration time
5 s
0.1–3600s
Deceleration time during traverse
operation
I001252E
Fig. 6-136:
Traverse function
Output
frequency
Traverse operation
Time [s]
ON
ON
STF (STR)
X37
f0: set frequency
f1: amplitude amount from
the set frequency
(f0
×
Pr. 593/100)
f2: compensation amount
at transition from
acceleration to
deceleration
(f1
×
Pr. 594/100)
f3: compensation amount
at transition from
deceleration to
acceleration
(f1
×
Pr. 595/100)
t1: time from acceleration
during traverse operation
(Time from (f0 + f1)
to (f0
−
f1) (Pr. 597)
t2: time from deceleration
during traverse operation
(Time from (f0
−
f1)
to (f0 + f1) (Pr. 596)
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......