Parameter
Parameter overview
FR-D700 SC EC
6 - 21
These parameters are communication parameters that are not cleared when parameter
clear (all clear) is executed from RS485 communication. (Refer to section 6.18 for RS485
communication).
Func-
tion
Parameter
Name
Incre-
ments
Initial
value
Setting
range
Description
Para-
meter
copy
Para-
meter
clear
All
Para-
meter
clear
Refer
to
page
Related
parameter
s
✔
: enabled
—: disabled
Setting of the magnitude of
frequency change by digital dial
295
Magnitude of
frequency change
setting
0,01
0
0
Invalid
✔
✔
✔
0.01/0.10/
1.00/10.00
The setting increments when the
set frequency is changed by the
setting dial can be set.
Password function
296
Password lock level
1
9999
1–6/
101–106
Select restriction level of parame-
ter reading/ writing when a
password is registered.
✔
—
✔
9999
No password lock
297
Password lock/unlock
1
9999
1000–9998
Register a 4-digit password
✔
—
✔
(0–5)
Displays password unlock error
count. (Reading only) (Valid when
Pr. 296 = "101" to "106")
(9999)
No password lock (Reading only)
—
298
299
Refer to Pr. 58
Communication
338
Communication opera-
tion command source
1
0
0
Operation command source
communication
✔
✔
✔
1
Operation command source exter-
nal (start/stop)
339
Communication speed
command source
1
0
0
Speed command source commu-
nication
✔
✔
✔
1
Speed command source external
(Frequency setting from commu-
nication is invalid, terminal 2 set-
ting from external is valid)
2
Speed command source external
(Frequency setting from commu-
nication is valid, terminal 2 setting
from external is invalid)
551
PU mode operation
command source
selection
1
9999
2
Selects the PU connector as the
PU operation mode control source
✔
✔
✔
4
Selects the operation panel as the
PU operation mode control
source.
9999
Parameter unit automatic
recognition
Normally, operation panel is the
command source. When the para-
meter unit is connected to the PU
connector, PU is the command
source.
—
340
Refer to Pr. 79
342
343
Refer to Pr. 117 to Pr. 124
450
Refer to Pr. 71
Tab. 6-1:
Parameter overview (21)
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......