Parameter
Communication operation and settings
FR-D700 SC EC
6 - 193
6.18
Communication operation and settings
6.18.1 PU
connector
Using the PU connector, you can perform communication operation from a personal computer
etc. When the PU connector is connected with a personal, FA or other computer by a commu-
nication cable, a user program can run and monitor the inverter or read and write to parameters.
Purpose
Parameters that must be set
Refer to
Section
Communication operation from
PU connector
Initial setting of computer link
communication (PU connector)
Pr. 117–Pr. 124
Modbus-RTU communication
specification
Pr. 117, Pr. 118,
Pr. 120, Pr. 122,
Pr. 343, Pr. 502
Pr. 549
Restrictions on parameter write
through communication
Communication E²PROM write selection
Pr. 342
Fig. 6-96:
PU connector pin-outs
I002002E
Pin Number
Name
Description
1)
SG
Earth (Ground) (connected to terminal 5)
2)
—
Operation panel power supply
3)
RDA
Inverter
4)
SDB
Inverter send
−
5)
SDA
Inverter send+
6)
RDB
Inverter receive
−
7)
SG
Earth (Ground) (connected to terminal 5
8)
—
Operation panel power supply
Tab. 6-48:
PU connector (terminal description)
NOTES
Pins No. 2) and 8) provide power to the operation panel or parameter unit. Do not use these
pins for RS485 communication.
Do not connect the PU connector to the computer's LAN board, FAX modem socket or tele-
phone modular connector. The product could be damaged due to differences in electrical
specifications.
8) to 1)
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......