Special operation
Parameter
6 - 242
6.19 Special
operation
6.19.1
PID control (Pr. 127 to Pr. 134, Pr. 575 to Pr. 577)
The inverter can be used to exercise process control, e.g. flow rate, air volume or pressure.
The terminal 2 input signal or parameter setting is used as a set point and the terminal 4 input
signal used as a feedback value to constitute a feedback system for PID control.
Purpose
Parameters that must be set
Refer to
Section
Perform process control such as
pump and air volume.
PID control
Pr. 127–Pr. 134,
Pr. 575–Pr. 577
Dancer control
PID control (dancer control setting)
Pr. 44, Pr. 45,
Pr. 128–Pr. 134
Traverse function
Traverse function
Pr. 592–Pr. 597
Avoid over voltage alarm due to
regeneration by automatic adjust-
ment of output frequency
Regeneration avoidance function
Pr. 882, Pr. 883,
Pr. 885, Pr. 886