Adjust the output torque (current) of the motor
Parameter
6 - 38
Limit the stall prevention operation and fast-response current limit operation according
to the operating status (Pr. 156)
Refer to the following table and select whether fast-response current limit operation will be per-
formed or not and the operation to be performed at OL signal output:
Since both fast-response current limit and stall prevention are not activated, OL signal and
E.OLT are not output.
The settings "100" and "101" allow operations to be performed in the driving and regener-
ation modes, respectively. The setting "101" disables the fast-response current limit in the
driving mode.
OL signal is not output at fast-response current limit operation.
Pr. 156
Setting
Fast-Re-
sponse Cur-
rent Limit
Stall Prevention Operation Level
OL Signal Output
Acceleration
Constant
Speed
Deceleration
Without Alarm
Stop with
Alarm "E.OLT"
0
✔
✔
✔
✔
✔
—
1
—
✔
✔
✔
✔
—
2
✔
—
✔
✔
✔
—
3
—
—
✔
✔
✔
—
4
✔
✔
—
✔
✔
—
5
—
✔
—
✔
✔
—
6
✔
—
—
✔
✔
—
7
—
—
—
✔
✔
—
8
✔
✔
✔
—
✔
—
9
—
✔
✔
—
✔
—
10
✔
—
✔
—
✔
—
11
—
—
✔
—
✔
—
12
✔
✔
—
—
✔
—
13
—
✔
—
—
✔
—
14
✔
—
—
—
15
—
—
—
—
16
✔
✔
✔
✔
—
✔
17
—
✔
✔
✔
—
✔
18
✔
—
✔
✔
—
✔
19
—
—
✔
✔
—
✔
20
✔
✔
—
✔
—
✔
21
—
✔
—
✔
—
✔
22
✔
—
—
✔
—
✔
23
—
—
—
✔
—
✔
24
✔
✔
✔
—
—
✔
25
—
✔
✔
—
—
✔
26
✔
—
✔
—
—
✔
27
—
—
✔
—
—
✔
28
✔
✔
—
—
—
✔
29
—
✔
—
—
—
✔
30
✔
—
—
—
31
—
—
—
—
100 D
✔
✔
✔
✔
✔
—
100 R
—
—
—
—
101 D
—
✔
✔
✔
✔
—
101 R
—
—
—
—
Tab. 6-3:
Setting of parameter 156 (D = Driving, R = Regeneration)
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......