Frequency setting by external terminals
Parameter
6 - 58
During jog operation or PID control operation, the remote setting function is invalid.
Set frequency = 0Hz
●
Even when the remotely-set frequency is cleared by turning on the RL (clear) signal after
turn off (on) of both the RH and RM signals, the inverter operates at the remotely-set
frequency stored in the last operation if power is reapplied before one minute has elapsed
since turn off (on) of both the RH and RM signals.
●
When the remotely-set frequency is cleared by turning on the RL (clear) signal after turn off
(on) of both the RH and RM signals, the inverter operates at the frequency in the remotely-
set frequency cleared state if power is reapplied after one minute has elapsed since turn off
(on) of both the RH and RM signals.
I001134C
Fig. 6-25:
Outputting the remotely-set frequency stored last time
I001135C
Fig. 6-26:
Outputting the current set frequency
b
CAUTION:
When Pr. 59 is set to "1" the motor will restart automatically after a power failure if
there is an active rotation direction signal.
Acceleration RH
Deceleration RM
Clear RL
Forward rotation STF
Power supply
Remotely-set frequency stored last time
< 1 minute
Output
frequency [Hz]
Remotely-set frequency stored last time
ON
ON
ON
ON
ON
ON
OFF
Time
Acceleration RH
Deceleration RM
Clear RL
Forward rotation STF
Power supply
Operation is performed at the set
frequency 0Hz.
> 1 minute
Output
frequency [Hz]
Remotely-set frequency stored last time
ON
ON
ON
ON
ON
ON
Time
OFF
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......