55
Frequency monitoring
reference
0.01Hz
50Hz
0–400Hz
Set the full-scale value to output
the output frequency monitor
value to terminal AM.
✔
✔
✔
56
Current monitoring
reference
0.01
Rated
inverter
output
current
0–500
Set the full-scale value to output
the output current monitor value
to terminal AM.
✔
—
✔
Restart operation after in
stantaneous power failure
57
Restart coasting time
0.1s
9999
0
The coasting time is as follows:
FR-D720S-070SC or less,
FR-D740-036SC or less:. . . . 1 s,
FR-D720S-100SC,
FR-D740-050SC or more:. . . 2 s
✔
✔
✔
0.1–5s
Set the waiting time for inverter-
triggered restart after an instanta-
neous power failure.
9999
No restart
58
Restart cushion time
0,1 s
1 s
0–60 s
Set a voltage starting time at
restart.
✔
✔
✔
162
Automatic restart after
instantaneous power
failure selection
1
1
0
With fre-
quency search
When using the
frequency search,
consider the wir-
ing length limit.
(Refer to page
3-11.)
✔
✔
✔
1
Without fre-
quency search
(Reduced
voltage sys-
tem)
10
Frequency
search at
every start
11
Reduced
voltage sys-
tem at every
start
165
Stall prevention opera-
tion level for restart
0.1%
150%
0–200%
Consider the rated inverter current
as 100% and set the stall preven-
tion operation level during restart
operation.
✔
✔
✔
298
Frequency search gain
1
9999
0–32767
When offline auto tuning is per-
formed under V/f control, fre-
quency search gain necessary for
frequency search for automatic
restart after instantaneous power
failure is set as well as the motor
constants (R1).
✔
—
✔
9999
Uses the Mitsubishi motor (SF-JR,
SF-HRCA) constants
299
Rotation direction
detection selection at
restarting
1
0
0
Without rotation direction detection
✔
✔
✔
1
With rotation direction detection
9999
When Pr. 78 = "0", the rotation
direction is detected.
When Pr. 78 = "1", "2", the rotation
direction is not detected.
611
Acceleration time at a
restart
0.1s
9999
0–3600s
Set the acceleration time to reach
the set frequency at a restart.
✔
✔
✔
9999
Acceleration time for restart is the
normal acceleration time (e.g.
Pr. 7).
Tab. 6-1:
Parameter overview (7)
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......