Parameter
Parameter overview
FR-D700 SC EC
6 - 23
Func-
tion
Parameter
Name
Incre-
ments
Initial
value
Setting
range
Description
Para-
meter
copy
Para-
meter
clear
All
Para-
meter
clear
Refer
to
page
Related
parameter
s
✔
: enabled
—: disabled
Current average
monitor signal
555
Current average time
0.1s
1s
0.1–1.0s
Set the time taken to average the
current during start bit output
(1s).
✔
✔
✔
556
Data output mask time
0.1s
0s
0–20s
Set the time for not obtaining
(mask) transient state data.
✔
✔
✔
557
Current average value
monitor signal output
reference current
0.01A
Rated
inverter
current
0–500A
Set the reference (100%) for out-
putting the signal of the current
average value
✔
✔
✔
—
561
Refer to Pr. 9
563
564
Refer to Pr. 52
571
Refer to Pr. 13
575
–
577
Refer to Pr. 127
Tr
averse function
592
Traverse function
selection
1
0
0
Traverse function invalid
✔
✔
✔
1
Traverse function is valid only in
the External operation mode
2
Traverse function is valid
independently of operation mode
593
Maximum amplitude
amount
0.1%
10%
0–25%
Amplitude amount during traverse
operation
✔
✔
✔
594
Amplitude
compensation amount
during deceleration
0.1%
10%
0–50%
Compensation amount at the time
of amplitude inversion
(acceleration to deceleration)
✔
✔
✔
595
Amplitude
compensation amount
during acceleration
0.1%
10%
0–50%
Compensation amount at the time
of amplitude inversion
(deceleration to acceleration)
✔
✔
✔
596
Amplitude acceleration
time
0.1s
5s
0.1–3600s
Acceleration time during traverse
operation
✔
✔
✔
597
Amplitude deceleration
time
0.1s
5s
0.1–3600s
Deceleration time during traverse
operation
✔
✔
✔
—
611
Refer to Pr. 57
Reduce mechanical
resonance
653
Speed smoothing
control
0.1%
0
0–200%
The torque fluctuation is reduced
to reduce vibration due to
mechanical resonance.
✔
✔
✔
—
665
Refer to Pr. 882
872
Refer to Pr. 251
Tab. 6-1:
Parameter overview (23)
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......