Operation
Operation panel
FR-D700 SC EC
4 - 9
Key
Function
Description
Digital dial
Used to change the frequency setting and parameter values.
Press to display the following:
Displays the set frequency in the monitor mode
Currently set value is displayed during calibration
Displays the order in the faults history mode
Rotation direction
RUN command for forward/reverse rotation.
The rotation direction can be selected by setting Pr. 40.
Stop operation/
Fault reset
Used to stop RUN command.
Fault can be reset when protective function is activated (fault).
Mode switch over
Used to change each setting mode.
Pressing PU/EXT simultaneously changes the operation mode
(refer to section 4.3.3).
Pressing for a while (more than 2s) can lock operation (refer to
section 4.3.4).
Write settings
If pressed during operation, monitor changes as below:
Operation mode
switch over
Used to switch between the PU and external operation mode. When
using the external operation mode (operation using a separately
connected frequency setting potentiometer and start signal), press
this key to light up the EXT indication. (Press MODE simultanesouly
(min. 0.5s) or change Pr. 79 setting to change to combined mode.)
PU:
PU operation mode
EXT: External operation mode (The motor can be stopped via the
parameter unit by the STOP/RESET key. The display on the
control panel switches to PS.)
Tab. 4-3:
Keys of the operation panel
Running
frequency
Output
current
Output
voltage
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......