Operation
Operation panel
FR-D700 SC EC
4 - 15
4.3.5
Monitoring of output current and output voltage
Monitor display of output frequency, output current and output voltage can be changed by push-
ing the SET key during monitoring mode.
4.3.6
First priority monitor
Hold down the SET key for 1s to set monitor description to be appeared first in the monitor mode.
To return to the output frequency monitor, hold down the SET key for 1s after displaying the out-
put frequency monitor.
4.3.7
Digital dial push
Appears when PU operation mode or external/PU combined operation mode 1 is selected
(Pr. 79 = "3").
Push the digital dial to display the set frequency currently set.
I001740E
Fig. 4-10:
Monitoring of output current and output voltage
Fig. 4-11:
Display the set frequency currently set
I001067E
Press the MODE key during operation to choose
the output frequency monitor.
(Hz indication is lit.)
Independently of whether the inverter is running
in any operation mode or at a stop, the output
current monitor appears by pressing the SET key.
(A indication is lit.)
Press the SET key to show the output voltage
monitor.
(Hz and A indication are turned off.)
Operation
Display
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......