![background image](http://html.mh-extra.com/html/mitsubishi-electric/fr-d720s-sc-ec/fr-d720s-sc-ec_instruction-manual_239222321.webp)
Parameter
Misoperation prevention and parameter setting restriction
FR-D700 SC EC
6 - 171
Parameter operation during password lock/unlock
Reading/writing is unavailable when there is restriction to reading by the Pr. 160 setting.
Unavailable during during operation.
Correct password will not unlock the restriction.
Parameter operation
Unlocked
Password
registered
Locked
Pr. 296 = 9999
Pr. 297 = 9999
Pr. 296
≠
9999
Pr. 297 = 9999
Pr. 296
≠
9999
Pr. 297 = 0–4
(Read value)
Pr. 296 = 101–106
Pr. 297 = 5
(Read value)
Pr. 296
Read
✔
✔
✔
✔
Write
✔
✔
—
—
Pr. 297
Read
✔
✔
✔
✔
Write
—
✔
✔
✔
Performing
parameter clear
✔
✔
—
—
Performing
parameter all clear
✔
✔
✔
✔
Performing
parameter copy
✔
✔
—
—
Tab. 6-35:
Parameter operation during password lock/unlock
NOTES
When Pr. 296 = "4, 5, 104, 105" and using the parameter unit (FR-PU04/FR-PU07), PU JOG
operation is unavailable.
When writing is restricted from PU mode operation command (Pr. 296 = 1, 2, 4, 5, 101, 102,
104, 105), switching of operation mode by easy setting mode is unavailable.
During password lock, parameter copy of the parameter unit (FR-PU07) cannot be
performed.
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......