Monitor display and monitor output signals
Parameter
6 - 114
쑶
NOTES
By setting "0" in Pr. 52, the monitoring of output speed to alarm display can be selected in
sequence by the SET key.
When the operation panel is used, the displayed units are Hz and A only and the others are
not displayed.
The monitor set in Pr. 52 is displayed in the third monitor position. However, change the out-
put current monitor for the motor load factor.
The monitor displayed at powering on is the first monitor. Display the monitor to be displayed
on the first monitor and press the SET key for 1s. (To return to the output frequency monitor,
hold down the SET key for 1s after displaying the output frequency monitor.)
I001800E
Fig. 6-60:
Displaying various types of monitor
Example
쑴
When Pr. 52 is set to "20" (cumulative energizing time), the monitor is displayed on the oper-
ation panel as described below.
I001801C
Fig. 6-61:
Selection of the third monitor
Power on monitor (first monitor) Second monitor
Third monitor
Alarm monitor
Output frequency
Output current
Output voltage
With
fault
Power on monitor (first monitor) Second Third
monitor
Alarm
monitor
Output frequency
Output current
Cumulative energizing time
With
fault
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......