Parameter
Communication operation and settings
FR-D700 SC EC
6 - 215
Setting items and set data
After completion of parameter setting, set the instruction codes and data then start communi-
cation from the computer to allow various types of operation control and monitoring.
Item
Read/
Write
Instruction
Code
Data Description
Number
of Data
Digits
(Format)
Operation Mode
Read
H7B
H0000: Network operation
H0001: External operation
H0002: PU operation
4
(B, E/D)
Write
HFB
4
(A, C/D)
Monitor
Output frequency/
speed
Read
H6F
H0000 to HFFFF:
Output frequency in 0.01Hz increments
Speed increments 1/0.001
(when Pr. 37 = 0.01 to 9998)
When "0.01 to 9998" is set in Pr. 37 and "01"
in instruction code HFF, the increments
change to 0.001 and the data format is E2.
When "100" is set in Pr. 52, the monitor value
is different depending on whether the inverter
is at a stop or running. (Refer to section
6.10.2.)
4
(B, E/D)
6
(B, E2/D)
Output current
Read
H70
H0000 to HFFFF:
Output current (hexadecimal) in 0.01A incre-
ments
4
(B, E/D)
Output voltage
Read
H71
H0000 to HFFFF:
Output voltage (hexadecimal) in 0.1V
increments
4
(B, E/D)
Special monitor
Read
H72
H0000 to HFFFF:
Monitor data selected in instruction code HF3
When "0.01 to 9998" is set in Pr. 37 and "01"
in instruction code HFF, the data format is
E2.
4
(B, E/D)
6
(B, E2/D)
Special monitor
selection No.
Read
H73
H01 to H40:
Monitor selection data
(Refer to Tab. 6-60 on page 6-219.)
2
(B, E1/D)
Write
HF3
2
(A1, C/D)
Fault definition
Read
H74 to H77
H0000 to HFFFF:
(Refer to Tab. 6-61 on page 6-220.)
4
(B, E/D)
Run command (extended)
Write
HF9
You can set the control input commands
such as the forward rotation signal (STF) and
reverse rotation signal (STR).
(Refer to page 6-221 for details.)
4
(A, C/D)
Run command
Write
HFA
2
(A1, C/D)
Inverter status monitor
(extended)
Read
H79
You can monitor the states of the output sig-
nals such as forward rotation, reverse rota-
tion and inverter running (RUN).
4
(B, E/D)
Inverter status monitor
Read
H7A
2
(B, E1/D)
Tab. 6-57:
Setting of the instruction codes and data (1)
Latest alarm
Second fault in past
Fourth fault in past
Sixth fault in past
Eighth fault in past
Third fault in past
Fifth fault in past
Seventh fault in past
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......