Connection of stand-alone option units
Wiring
3 - 38
b
CAUTION:
●
If the transistors in the brake unit should become faulty, the resistor can be
unusually hot, causing a fire.
Therefore, install a magnetic contactor on the inverters input side to configure a
circuit so that a current is shut off in case of fault.
●
Do not remove a jumper across terminal P/+ and P1 except when connecting a DC
reactor.
NOTE
Set "1" in Pr. 0 "Brake mode selection" of the FR-BU2 to use GRZG type discharging resistor.