Parameter
Frequency setting by analog input (terminal 2, 4)
FR-D700 SC EC
6 - 149
Refer to the following table and set Pr. 73 and Pr. 267. The half-tone screened areas indicate
the main speed setting.
The terminal used for the AU signal input, set "4" in Pr. 178 to Pr. 182 to assign functions.
Pr. 73
Terminal 2
Terminal 4
Polarity Reversible
AU Signal
0
0–10V
OFF
—
No
1
(initial
value)
0–5V
10
0–10V
Yes
11
0–5V
0
—
ON
According to Pr. 267:
0: 4–20mA (initial value)
1: 0–5V
2: 0–10V
No
1
(initial
value)
10
—
Yes
11
Tab. 6-28:
Setting of parameter 73 and 267
NOTES
Turn the AU signal on to make terminal 4 valid.
Make sure that the parameter and switch settings are the same. Different setting may cause
a fault, failure or malfunction.
Use Pr. 125 (Pr. 126) "Frequency setting gain" to change the maximum output frequency at
input of the maximum output frequency command voltage (current). At this time, the com-
mand voltage (current) need not be input. Also, the acceleration/deceleration time, which is a
slope up/down to the acceleration/deceleration reference frequency, is not affected by the
change in Pr. 73 setting.
When Pr. 561
≠
9999, terminal 2 is not available for analog frequency command.
Changing the terminal assignment using Pr. 178 to Pr. 182 may affect the other functions.
Make setting after confirming the function of each terminal.
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......