Parameter overview
Parameter
6 - 18
Func-
tion
Parameter
Name
Incre-
ments
Initial
value
Setting
range
Description
Para-
meter
copy
Para-
meter
clear
All
Para-
meter
clear
Refer
to
page
Rel
a
ted
pa
ramet
e
rs
✔
: enabled
—: disabled
Function assignment
of output terminal
190
RUN terminal function
selection
1
0
0/1/3/4/7/8/
11–16/25/
26/46/47/
64/70/80/
81/90/91/
93/95/96/
98/99/100/
101/103/
104/107/
108/111–
116/125/
126/146/
147/164//
170/180/
181/190/
191/193/
195/196/
198/199/
9999
0/100:
Inverter running
1/101:
Up to frequencych
3/103:
Overload alarm
4/104:
Output frequency
detection
7/107:
Regenerative brake
prealarm
8/108:
Electronic thermal relay
function prealarm
11/111: Inverter operation ready
12/112: Output current detection
13/113: Zero current detection
14/114: PID lower limit
15/115: PID upper limit
16/116: PID forward/reverse
rotation output
25/125: Fan fault output
26/126: Heatsink overheat
prealarm
46/146: During deceleration at
occurrence of power fail-
ure (retained until release)
47/147: PID control activated
64/164: During retry
70/170: PID output interruption
80/180: Safety monitor output
81/181: Safety monitor output 2
90/190: Life alarm
91/191: Alarm output 3
(power-off signal)
93/193: Current average monitor
95/195: Maintenance timer alarm
96/196: Remote output
98/198: Minor fault output
99/199: Alarm output
9999:
No function
0–99:
Source logic
100–199: Sink logic
✔
—
✔
192
ABC terminal function
selection
1
99
0/1/3/4/7/8/
11–16/25/
26/46/47/
64/70/80/
81/90/91/
95/96/98/
99/
100/101/
103/104/
107/108/
111–116/
125/126/
146/147/
164/170/
180/181/
190/191/
195/196/
198/199/
9999
✔
—
✔
197
Funktionszuweisung
SO-Klemme
80
0/1/3/4/7/8/
11–16/25/
26/46/47/
64/70/80/
81/90/91/
93/95/96/
98/99/100/
101/103/
104/107/
108/
111–116/
125/126/
146/147/
164/170/
180/181/
190/191/
193/195/
196/198/
199
✔
—
✔
—
232
–
239
Refer to Pr. 4 to Pr. 6
240
Refer to Pr. 72
241
Refer to Pr. 125 and Pr. 126
Increase cooling
fan life
244
Cooling fan operation
selection
1
1
0
Operates at power on
Cooling fan on/off control invalid
(The cooling fan is always on at
power on.)
✔
✔
✔
1
Cooling fan on/off control valid
Tab. 6-1:
Parameter overview (18)
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......