Useful functions
Parameter
6 - 270
6.20 Useful
functions
6.20.1
Cooling fan operation selection (Pr. 244)
You can control the operation of the cooling fan (FR-D720S-070SC or more, FR-D740-036SC
or more) built in the inverter.
The above parameter can be set when Pr. 160 = 0.
In either of the following cases, fan operation is regarded as faulty, "FN" is shown on the oper-
ation panel, and the fan fault "FAN" and alarm "LF" signals are output.
Pr. 244 = 0
When the fan comes to a stop with power on.
Pr. 244 = 1
When the fan stops during the fan ON command while the inverter is running.
For the terminal used for FAN signal output, set "25" (source logic) or "125" (sink logic) to any
of Pr. 190, Pr. 192 or Pr. 197 "Output terminal function selection", and for the LF signal, set "98"
(source logic) or "198" (sink logic).
Purpose
Parameters that must be set
Refer to
Section
Increase cooling fan life
Cooling fan operation selection
Pr. 244
To determine the maintenance time
of parts.
Inverter part life display
Pr. 255–Pr. 259
Maintenance output function
Pr. 503–Pr. 504
Current average value monitor signal
Pr. 555–Pr. 557
Freely available parameter
Free parameter
Pr. 888–Pr. 889
Pr. No.
Name
Initial
Value
Setting
Range
Description
Parameters referred to
Refer to
Section
244
Cooling fan operation
selection
1
0
Operates at power on
Cooling fan on/off control invalid (The
cooling fan is always on at power on)
190/192/
197
Output terminal
function selection
1
Cooling fan on/off control valid
The fan is always on while the inverter
is running. During a stop, the inverter
status is monitored and the fan
switches on-off according to the tem-
perature of the heatsink.
NOTE
When terminal assignment is changed using Pr. 190, Pr. 192 or Pr. 197, the other functions
may be affected. Please make setting after confirming the function of each terminal.
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......