Parameter overview
Parameter
6 - 6
Func-
tion
Parameter
Name
Incre-
ments
Initial
value
Setting
range
Description
Para-
meter
copy
Para-
meter
clear
All
Para-
meter
clear
Refer
to
page
Rel
a
ted
pa
ramet
e
rs
✔
: enabled
—: disabled
Display functions
52
DU/PU main display
data selection
1
0
0/5/8–12/
14/20/
23–25/
52–55/61/
62/64/100
Selects monitor to be displayed on
the operation panel and parameter
unit and monitor to be output to
the terminal AM.
0:
Output frequency (Pr. 52)
1:
Output frequency (Pr. 158)
2:
Output current (Pr. 158)
3:
Output voltage (Pr. 158)
5:
Frequency setting value
8:
Converter output voltage
9:
Regenerative brake duty
10: Electronic thermal relay
function load factor
11: Output current peak value
12: Converter output voltage
peak value
14: Output power
20: Cumulative energization
time (Pr. 52)
21: Reference voltage output
(Pr. 158)
23: Actual operation time (Pr. 52)
24: Motor load factor
25: Cumulative power (Pr. 52)
52: PID set point
53: PID measured value
54: PID deviation (Pr. 52)
55: I/O terminal status (Pr. 52)
61: Motor thermal load factor
62: Inverter thermal load factor
64: PTC thermistor resistance
100: Set frequency is displayed
during a stop and output
frequency is displayed during
operation (Pr. 52).
✔
✔
✔
158
AM terminal function
selection
1
1
1–3/5/8–12/
14/21/24/
52/53/61/62
✔
✔
✔
170
Watt-hour meter clear
1
9999
0
Set "0" to clear the watt-hour meter
monitor.
✔
—
✔
10
Set the maximum value when
monitoring from communication
to 0 to 9999kWh.
9999
Set the maximum value when
monitoring from communication
to 0 to 65535kWh.
171
Operation hour meter
clear
1
9999
0/9999
Set "0" in the parameter to clear
the watt hour monitor.
Setting "9999" has no effect.
✔
✔
✔
268
Monitor decimal digits
selection
1
9999
0
Displays the monitor as integral
value.
✔
—
✔
1
Displays the monitor in incre-
ments of 0.1.
9999
No fixed decimal position
563
Energizing time
carrying-over times
1
0
0–65535
The numbers of cumulative ener-
gizing time monitor exceeded
65535h is displayed.
Reading only
—
—
—
564
Operating time
carrying-over times
1
0
0–65535
The numbers of operation time
monitor exceeded 65535h is dis-
played.
Reading only
—
—
—
891
Cumulative power
monitor digit shifted
times
1
9999
0–4
Set the number of times to shift
the cumulative power monitor
digit. Clamp the monitoring value
at maximum.
✔
✔
✔
9999
No shift
Clear the monitor value when it
exceeds the maximum value.
Tab. 6-1:
Parameter overview (6)
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......