Basic settings
PU operation mode
FR-D700 SC EC
5 - 29
5.2.5
Perform frequency setting by analog current input
An external current source is connection to the frequency inverter for setpoint default setting.
●
Pr. 79 "Operation mode selection" must be set to "4" (external/PU combined operation
mode 2).
●
Turn the AU signal on.
●
Use the RUN key to give a start command.
I0020206E
Fig. 5-18:
Frequency setting by analog current input
NOTE
For the analog current input (0/4 to 20 mA) to become effective for setpoint default setting,
the AU signal on the AU terminal must be activated. This is done, for example, by means of
a bridge as shown in Fig. 5-18.
Power supply
Motor
Inverter
Current signal
source
(0/4–20mA DC)
AU signal
Operation
panel