Parameter
Selection of operation mode and operation location
FR-D700 SC EC
6 - 173
Operation mode basics
The operation mode is to specify the source of inputting the start command and set frequency
of the inverter.
●
Select the "external operation mode" when performing operation by basically using the
control circuit terminals and providing potentiometers, switches, etc. externally.
●
Select the "PU operation mode" when inputting the start command and frequency setting
through communication from the operation panel, parameter unit (FR-PU04/FR-PU07) or
PU connector.
●
Select the "network operation mode (NET operation mode)" when the commands are
applied from the RS485 communication with the PU connector.
The operation mode can be selected from the operation panel or with the communication
instruction code.
I002001E
Fig. 6-89:
Operation modes of the inverter
NOTES
Either "3" or "4" may be set to select the PU/external combined mode.
The stop function (PU stop selection) activated by pressing the STOP/RESET key of the
operation panel and parameter unit (FR-PU04/FR-PU07) is valid even in other than the PU
operation mode in the initial setting. (Refer to Pr. 75 "Reset selection/disconnected PU
detection/PU stop selection" (section 6.16.1).)
Inverter
External terminals
Network
operation mode
External
operation
mode
Potentiometer
Switch
PLC
Personal computer
PU operation mode
Operation
panel
PU connector
FR-PU07
GOT
Personal computer
PU operation
mode
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......