Parameter
Parameter overview
FR-D700 SC EC
6 - 5
Func-
tion
Parameter
Name
Incre-
ments
Initial
value
Setting
range
Description
Para-
meter
copy
Para-
meter
clear
All
Para-
meter
clear
Refer
to
page
Rel
a
ted
pa
ramet
e
rs
✔
: enabled
—: disabled
A
void mechanical
resonance points
31
Frequency jump 1A
0.01Hz
9999
0–400Hz/
9999
1A to 1B, 2A to 2B, 3A to 3B are
frequency jumps
9999: Function invalid
✔
✔
✔
32
Frequency jump 1B
0.01Hz
9999
0–400Hz/
9999
✔
✔
✔
33
Frequency jump 2A
0.01Hz
9999
0–400Hz/
9999
✔
✔
✔
34
Frequency jump 2B
0.01Hz
9999
0–400Hz/
9999
✔
✔
✔
35
Frequency jump 3A
0.01Hz
9999
0–400Hz/
9999
✔
✔
✔
36
Frequency jump 3B
0.01Hz
9999
0–400Hz/
9999
✔
✔
✔
Speed display and
speed setting
37
Speed display
0.001
0
0
Frequency display, setting
✔
✔
✔
0.01–9998
Set the machine speed at 60Hz.
RUN key rotation
direction selection
40
RUN key rotation direc-
tion selection
1
0
0
Forward rotation
✔
✔
✔
1
Reverse rotation
Detection of output
frequency (SU, FU)
41
Up-to-frequency
sensitivity (SU output)
0.1%
10%
0–100%
Set the level where the SU signal
turns on.
✔
✔
✔
42
Output frequency
detection (FU output)
0.01Hz
6Hz
0–400Hz
Set the frequency where the FU
signal turns on.
✔
✔
✔
43
Output frequency
detection for reverse
rotation
0.01Hz
9999
0–400Hz
Set the frequency where the FU
signal turns on in reverse rotation.
✔
✔
✔
9999
Same as Pr. 42 setting
—
44
45
Refer to Pr. 7 and Pr. 8
46
Refer to Pr. 0
47
Refer to Pr. 3
48
Refer to Pr. 22
—
51
Refer to Pr. 9
Tab. 6-1:
Parameter overview (5)
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......