Parameter overview
Parameter
6 - 14
Func-
tion
Parameter
Name
Incre-
ments
Initial
value
Setting
range
Description
Para-
meter
copy
Para-
meter
clear
All
Para-
meter
clear
Refer
to
page
Rel
a
ted
pa
ramet
e
rs
✔
: enabled
—: disabled
Change of analog input frequency
,
adjustment of voltage, current
input and frequency (calibration)
125
Terminal 2 frequency
setting gain frequency
0.01Hz
50Hz
0–400Hz
Set the frequency of terminal 2
input gain (maximum).
✔
—
✔
126
Terminal 4 frequency
setting gain frequency
0.01Hz
50Hz
0–400Hz
Set the frequency of terminal 4
input gain (maximum).
✔
—
✔
241
Analog input display
unit switch over
1
0
0
Displayed in
%
Select the unit for
analog input dis-
play.
✔
✔
✔
1
Displayed in
V/mA
C2
(902)
Terminal 2 frequency
setting bias frequency
0.01Hz
0Hz
0–400Hz
Set the frequency on the bias side
of terminal 2 input.
✔
—
✔
C3
(902)
Terminal 2 frequency
setting bias
0.1%
0%
0–300%
Set the converted % of the bias
side voltage (current) of terminal 2
input.
✔
—
✔
C4
(903)
Terminal 2 frequency
setting gain
0.1%
100%
0–300%
Set the converted % of the gain
side voltage of terminal 2 input.
✔
—
✔
C5
(904)
Terminal 4 frequency
setting bias frequency
0.01Hz
0Hz
0–400Hz
Set the frequency on the bias side
of terminal 4 input.
✔
—
✔
C6
(904)
Terminal 4 frequency
setting bias
0.1%
20%
0–300%
Set the converted % of the bias
side current (voltage) of terminal 4
input.
✔
—
✔
C7
(905)
Terminal 4 frequency
setting gain
0.1%
100%
0–300%
Set the converted % of the gain
side current (voltage) of terminal 4
input.
✔
—
✔
PID control
127
PID control automatic
switchover frequency
0.01Hz
9999
0–400Hz
Set the frequency at which the
control is automatically changed
to PID control.
✔
✔
✔
9999
Without PID automatic switchover
function
128
PID action selection
1
0
0
PID control invalid
✔
✔
✔
20
PID reverse
action
Measured value
input (terminal 4)
Set value (termi-
nal 2 or Pr. 133)
21
PID forward
action
40–43
Dancer con-
trol
Tab. 6-1:
Parameter overview (14)
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......