Acceleration and deceleration
Parameter
6 - 64
6.6.3
Acceleration and deceleration pattern (Pr. 29)
You can set the acceleration/deceleration pattern suitable for application.
The above parameter can be set when Pr. 160 = 0.
Linear acceleration/deceleration (Pr. 29 = 0, initial value)
For the inverter operation, the output frequency is made to change linearly (linear acceleration/
deceleration) to prevent the motor and inverter from excessive stress to reach the set frequency
during acceleration, deceleration, etc. when frequency changes. Linear acceleration/deceler-
ation has a uniform frequency/time slope (refer to Fig. 6-30).
Pr.
No.
Name
Initial
Value
Setting
Range
Description
Parameters referred to
Refer to
Section
29
Acceleration/deceleration
pattern selection
0
0
Linear acceleration/deceleration
3
7
8
20
Base frequency
Acceleration time
Deceleration time
Acceleration/
deceleration refer-
ence frequency
1
S-pattern acceleration/deceleration A
2
S-pattern acceleration/deceleration B
Fig. 6-30:
Characteristic for parameter 29 = 0
I000015C
Hz
t
fm
Output frequency
Time
linear
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......